Rinnai RE180iN review: the flow rate is real, the venting is the bill
180,000 BTU of natural gas does what no electric unit in this comparison can: two simultaneous showers in January. The purchase price is not the whole price.
On this page
Every other heater in this comparison is sold on a flow rate that needs a footnote. This one is not.
Rinnai advertises 8.5 GPM. Work it out independently: 180,000 BTU input at roughly 82% thermal efficiency is about 147,600 BTU of usable output, which at a 35 °F rise gives 8.4 GPM. The marketing figure and the arithmetic land within a rounding error of each other, which after four electric units quoting summer numbers is worth pausing on.
More importantly, the number that matters is also good. At a 70 °F rise — a genuine northern winter — this unit delivers 4.2 GPM. That is two simultaneous showers with margin. The largest electric heater here, at 28.8 kW and 120 amps, manages 2.8.
| Specification | Rinnai RE180iN |
|---|---|
| Output | |
| Input rating | 180,000 BTU/hr, natural gas |
| Advertised flow rate | 8.5 GPM |
| Real flow rate | |
| At 35 °F rise | 8.4 GPM The advertised figure is honest. 180,000 BTU in at roughly 82% thermal efficiency is about 147,600 BTU out, which is 8.4 GPM at a 35 °F rise — the arithmetic lands where the marketing does, which is rarer than it should be. |
| At 50 °F rise | 5.9 GPM |
| At 70 °F rise (northern winter) | 4.2 GPM Two simultaneous showers with margin, in January, in Minnesota. No electric unit in this class comes close. |
| Efficiency | |
| Design | Non-condensing |
| Thermal efficiency | ≈ 82% A condensing unit reaches 94–96%. The 12-point gap is the running cost you accept in exchange for a much cheaper box. |
| Venting | |
| Vent type required | Category III stainless steel, sealed This is the hidden cost. Non-condensing exhaust leaves the unit around 300 °F, so it cannot use PVC. Stainless concentric vent kits commonly run $300–$600 before labour, and a long or awkward run costs more than that. |
| Installation type | Indoor, wall-mounted The 'i' in RE180iN means indoor. Rinnai's own listing copy on this ASIN describes an outdoor model — that text is generic to the range and does not describe this unit. |
| Gas supply | |
| Fuel | Natural gas |
| Line sizing | 3/4 in typical, subject to run length and meter capacity 180,000 BTU is a large draw. A house already running a furnace, range and dryer often needs the meter and the run re-checked, which is a gas fitter's calculation and not a guess. |
| Electrical | |
| Supply | 120 V, standard outlet Gas heats the water, but the controls, fan and freeze protection are electric. No power, no hot water. |
| Control | |
| Maximum set temperature | 140 °F |
| Display | LED with maintenance reminders and error codes |
| Wi-Fi | Optional, via Controlr module Sold separately, unlike the APUS which includes it. |
| Physical | |
| Dimensions (W × H) | 14.05 in × 27.28 in |
| Weight | 54 lb (24.5 kg) |
| Heat exchanger material | Stainless steel |
| Ownership | |
| Warranty — heat exchanger | 15 years, limited |
| Warranty — parts | 5 years |
| Warranty — labour | 5 years, but only if registered within 90 days Miss the 90-day registration window and the labour cover drops to one year. On a unit that needs a professional for any warranty work, that is the most expensive box anyone forgets to tick. |
| Installation | Professional strongly recommended by Rinnai Gas, venting and a labour warranty that depends on correct installation. This is not a DIY unit. |
What non-condensing actually costs you
This is where the price of the box stops being the price of the heater.
A condensing gas heater extracts so much heat from the exhaust that the flue gas comes out cool and wet — cool enough to vent through PVC, which is cheap, light and easy to run. A non-condensing unit like this one sends exhaust out at around 300 °F, which PVC cannot carry. It requires Category III stainless steel, sealed.
The practical consequences:
- Parts: $300 to $600 for a straightforward short run with a wall termination.
- A long horizontal run, a roof termination, or an awkward path through finished space can double that.
- Labour is higher too, because stainless vent assembly is more exacting than solvent-welding plastic.
Rinnai's own condensing RU series avoids all of this and vents in PVC, which claws back much of its higher purchase price immediately, then keeps saving through 94–96% efficiency against roughly 82%. If your household uses a lot of hot water, run that comparison before committing to the RE.
The RE makes sense when the vent run is short and simple, and when the lower purchase price outweighs a modest efficiency gap over the life of the unit.
The 90-day warranty trap
The warranty on this unit is genuinely excellent, and part of it is easy to lose.
Registered within 90 days of installation:
- 15 years — heat exchanger, limited
- 5 years — parts
- 5 years — labour
Not registered within 90 days: the labour cover drops to one year. Everything else stands.
That sounds administrative until you consider what warranty service on a gas appliance involves. You cannot fix this yourself; any covered repair requires a qualified technician, and a call-out plus labour on a tankless heater runs $200 to $500 before parts. Losing years two through five of labour cover on an appliance expected to last fifteen years is a real financial exposure created by not filling in a form.
Do it the day the installer leaves. Keep the invoice — registration requires the installation date and usually the installer's details.
Where the gas advantage really comes from
It is worth being precise about why gas wins here, because it is not simply "gas is better."
Electric resistance heating is 100% efficient at the point of use, and this unit is only about 82%. On efficiency alone electric wins. What gas has is energy density in the supply: a 3/4 inch gas line can deliver 180,000 BTU per hour without anyone rewiring anything, whereas delivering the electrical equivalent means 100 to 120 amps, three double-pole breakers, and frequently a service upgrade.
So the comparison is not really about the heaters. It is:
- Electric — cheaper box, sometimes far more expensive install, hard ceiling on output.
- Gas — dearer box, venting bill, but the supply can carry three times the power.
In a warm climate where 24 kW is enough, electric is usually the cheaper total. In a cold climate where you need 4 GPM, gas is the only route that does not involve rebuilding your electrical service. APUS against EcoSmart works through this decision in detail, and the electrical requirements for electric tankless units covers what the electric alternative demands.
Sizing it honestly
The arithmetic, as ever:
GPM = BTU output ÷ (temperature rise × 8.34 × 60)
At 147,600 BTU of usable output:
- 35 °F rise — southern summer — 8.4 GPM
- 50 °F rise — mid-Atlantic — 5.9 GPM
- 70 °F rise — northern winter — 4.2 GPM
Against 2.0 GPM shower heads, the winter figure is two showers running together with capacity to spare for a sink. That is the definition of whole-home service, and it is why this unit is in a different conversation from the electric options. Our the GPM calculator runs the numbers for your own region, and how to size a tankless water heater explains the method.
One caution on gas supply: 180,000 BTU per hour is a large draw. A house already running a furnace, a range and a gas dryer may need the meter capacity and the pipe run re-evaluated. That is a gas fitter's calculation and it should happen before the unit is ordered, not after.
Gas supply is the other constraint people miss
Venting is the cost that surprises people. Gas supply is the one that occasionally stops the project altogether, and it is worth checking before the unit is ordered rather than after.
180,000 BTU per hour is a large continuous draw — larger than most furnaces. The question is not whether you have gas, but whether the meter and the pipe run can deliver that much on top of everything else that might be running at the same time.
A rough audit of a typical house:
- Furnace — 60,000 to 100,000 BTU/hr
- Range — 40,000 to 65,000 BTU/hr
- Gas dryer — 20,000 to 25,000 BTU/hr
- This heater — 180,000 BTU/hr
Add those and you are somewhere between 300,000 and 370,000 BTU/hr of connected load. A standard residential meter rated at 250,000 BTU/hr cannot serve that simultaneously, and the utility has to uprate it — usually free, but on their schedule rather than yours.
Pipe sizing is the second half. Capacity falls with distance, and a 3/4 inch line that is adequate at 20 feet may not be at 60. This is a gas fitter's calculation against a sizing table, not a judgement call, and getting it wrong produces a heater that ignites and then drops out under load — a fault that is very frustrating to diagnose after the fact because everything looks correctly installed.
Ask your installer to confirm both the meter capacity and the pipe sizing during the quote. It is ten minutes of work at that stage and a second visit if it is skipped.
Who should not buy this
- Anyone without a gas line. Running one for a water heater alone rarely pays back.
- Anyone with a long or complex vent path. Price the RU condensing version instead and vent it in PVC.
- Heavy hot water users. The efficiency gap compounds; the condensing unit is the better fifteen-year purchase.
- Anyone hoping to install it themselves. Gas, sealed venting, and a labour warranty contingent on correct fitting.
What works
- 4.2 GPM at a 70 °F rise. Two simultaneous showers in a northern winter, which no electric unit in this comparison approaches.
- The advertised 8.5 GPM is honest. 180,000 BTU at roughly 82% efficiency computes to 8.4 GPM at a 35 °F rise — the marketing lands where the arithmetic does.
- 15-year limited warranty on the heat exchanger, against 5 years for both Rheems and 7 for the Stiebel.
- No panel impact. It runs on a standard 120 V outlet, so there is no load calculation, no subpanel and no service upgrade.
- Rinnai's service network is the deepest in the category — parts and trained installers are available almost everywhere in the US.
What doesn't
- Non-condensing means Category III stainless venting. Exhaust leaves around 300 °F, so PVC is not permitted. Budget $300 to $600 in parts, more for a long or awkward run.
- The 5-year labour warranty becomes 1 year unless registered within 90 days. It is the most expensive box anyone forgets to tick.
- ≈82% thermal efficiency against 94–96% for a condensing unit. On heavy use that gap is real money over fifteen years.
- Only 16 Amazon ratings. Rinnai sells overwhelmingly through plumbing supply, so this listing is thin — you are buying on the brand's reputation, not on owner reports here.
- Professional installation is effectively mandatory. Gas, sealed venting and a labour warranty contingent on correct fitting. Add $800 to $2,000.
The verdict
This is the best whole-home tankless heater in this comparison, and the one whose true cost is furthest from its listed price.
The hardware deserves the score. Honest specifications, 4.2 GPM in a real winter, a 15-year exchanger warranty and the deepest service network in the category are all serious advantages, and none of the electric units here can match the output at any price.
Just budget for the whole thing rather than the box: roughly $1,200 for the unit, $300 to $600 for stainless venting, and $800 to $2,000 for a licensed installer. Then register it within 90 days. Do those three things and this is a fifteen-year appliance that will not disappoint you in February.
We may earn a commission if you buy through our links — here is how we are funded.
Check price on Amazon Opens Amazon in a new tab. Price and availability change — check before you buy.Questions people actually ask
What venting does the Rinnai RE180iN need?
Category III stainless steel, sealed. This is the consequence of non-condensing operation: exhaust leaves the unit at roughly 300 °F, far too hot for the PVC that condensing units are allowed to use. Stainless concentric kits commonly run $300 to $600 in parts for a short run, and a long horizontal run or a roof termination costs more. It is the single most underestimated line in the budget for this heater.
Is the Rinnai RE180iN indoor or outdoor?
Indoor. The 'i' in RE180iN denotes an interior unit — the exterior version is the RE180eN for natural gas or RE180eP for propane. Be careful here, because Rinnai's own Amazon listing copy for this ASIN describes outdoor models; that text is generic to the RE range and does not describe this unit. Buying the wrong one is an expensive mistake because the venting requirements differ completely.
How much does it cost to install a Rinnai RE180iN?
Budget $1,200 for the unit, $300 to $600 for Category III venting, and $800 to $2,000 for a licensed installer, so realistically $2,300 to $3,800 all in. If the gas line needs upsizing for a 180,000 BTU draw, add more. That is genuinely more than an electric tankless unit — until you price the electrical work an electric unit needs, at which point the two converge.
Do I need to register the warranty?
Yes, within 90 days of installation, and it matters more than it sounds. Registered, you get 15 years on the heat exchanger, 5 on parts and 5 on labour. Unregistered, the labour cover drops to one year while the rest stands. On an appliance where every warranty repair requires a qualified gas technician, losing four years of labour cover is the difference between a free repair and a $400 call-out.
RE180iN or RU180iN — what is the difference?
The RU is the condensing version: 94–96% thermal efficiency against roughly 82%, and it vents in PVC rather than stainless. It costs several hundred dollars more for the unit and saves most of that back on venting, then saves on gas every year afterwards. If your annual hot water use is high, the RU is the better long-run purchase. If use is moderate or the install is a straightforward short vent run, the RE is the cheaper total.
Will it work in a power cut?
No. Gas heats the water, but the ignition, fan, controls and freeze protection all run on 120 V. In an outage you have no hot water, and in sustained sub-freezing conditions the freeze protection is off exactly when it is needed. A small UPS covers the controls through most outages and is cheap insurance in a cold region.